from Fahrenheit to Celsius or from Celsius to Fahrenheit, press and hold the SUPERFREEZE key
for 5 seconds.
Setting the Temperature Control
You can set the temperature by pressing the UP and DOWN keys. When you press either of the
two keys for the first time, the LED readout will show the original temperature set previously.
(The temperature preset at the factory is F, or -18°C.)
The temperature you are setting will increase by one degree each time you press the UP key,
and will decrease by one degree each time you press the DOWN key.
The range of the temperature control is from -11°F to 11°F.
To view the set temperature at any time, press the UP or DOWN key. The set temperature will
flash in the display window for 5 seconds. After 5 seconds, the temperature inside the unit will
reappear in the display window.
Interior Light
The unit is equipped with an interior LED light which will be turned ON when the door is open.
SABBATH MODE
Sabbath mode is available for the observance of certain religious holidays. This mode turns off the
displays, interior light and audible alarms and prevents them from turning on again. Normal cooling
operations will still take place.
To initiate Sabbath mode, press the POWER and LIGHT keys at the same time for at least 5 seconds for
FF1532B / SPR316OS / FF64B / FF64BSS / SPR627OS, or press the POWER and SUPERFREEZE
keys at the same time for at least 5 seconds for SCFF1533B / SCFF52W / SCFF53B / SCFF53BSS /
SPFF51OS. The indicator light will flash four times and confirm that the Sabbath mode is ON.
Sabbath mode can be exited by repeating the above process. The Sabbath Mode will automatically turn
off after 96 hours.
TEMPERATURE MEMORY FUNCTION
In the event of a power interruption (power surge, breaker switch, etc.), the unit can remember the
previous temperature settings, and when the power is recovered, the cabinet temperature will return
to the same setting temperature as before the power went off.
DEFROSTING
The unit defrosts automatically in normal operating conditions.
The evaporator behind the rear wall of the unit defrosts automatically. The condensate collects in the
drainage channel behind the rear wall of the unit, and flows through the drainage hole into the drip tray
by the compressor where it evaporates.
NOTE:
If the unit is unplugged, or power is lost or turned off, you must wait 3 to 5 minutes before
restarting the unit. If you attempt to restart before this time delay, the unit will not start.
When you use the unit for the first time or restart the unit after it has been shut off for a long time,
there could be a few degrees variance between the temperature you select and the one indicated
on the LED readout. This is normal and is due to the length of the activation time. There should
not be a problem once the unit has been running for a few hours.