Dear Customer,
Thank you for buying our range hood. Please follow diagrams on pages
4-7 for proper installation, and carefully read the instructions below for
more on installation, plus information on optimum use and maintenance.
Note: The figures mentioned in this manual are on pages 4 through 10.
INSTALLATION
Hood installation on walls (pages 4-6)
Warning: Consult local regulations regarding fumes outlets. Do not
connect the hood to a fume, ventilation or hot air duct. Confirm that
room ventilation is appropriate with the local authorities. Make sure
the maximum air extraction flow rate for the appliances in the
room does not exceed 4 Pa (0.04 mbar). The room must have
adequate ventilation if an extractor hood is used simultaneously with
appliances that run on gas or other fuels. The evacuated air must
be extracted through ducts that are used for evacuating fumes from
appliances that run on gas or other fuels. Regulations regarding air
extraction must be complied with.
WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) or fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
Use rigid metal ductwork with a minimum diameter of 150 mm (about 4¾")
to evacuate fumes outside.
The above restrictions do not apply to hoods with no fumes outlet to
outside (recirculation system with activated charcoal filter).
Install the hood in line with the instructions on the template provided.
Use only with range hood cord-connection kits that have been investigated
and found acceptable for use with this model range hood.
The minimum distance to the hood must be at least 65 cm (about 25").